Condensation on windows in Spain: solutions

Guide · 10 min read · Costa Renova site team · updated

Windows steam up on the inside when the humid air in the home meets glass or a frame that is cold. The solutions run from least to most: ventilate and cut the steam, a dehumidifier, swap the glass for low-emissivity double glazing, or replace the window with a uPVC or thermally broken aluminium one at €350 to €900 per unit, VAT not included. If the mist is between the two panes of a double-glazed unit, the seal has failed and only a new sealed unit fixes it.

  • Fixed, itemised quote, free and with no obligation
  • Site visit within 48–72 h in Alicante and 45 km around
  • One project manager from start to finish
Illustrative image: aluminium window installation
Illustrative image: aluminium window installation.
On this page
  1. Condensation on windows: the short answer
  2. Solutions to condensation on windows: table from least to most
  3. Why windows steam up: humid air and a cold surface
  4. Solutions without building work: steam, ventilation and habits
  5. The glass: single, double and low-emissivity
  6. The frame: thermal break and uPVC
  7. The roller shutter box and the wall around it
  8. Condensation on windows in Alicante: old flats and coastal apartments
  9. Common mistakes
  10. When to call a professional

Condensation on windows: the short answer

Windows steam up on the inside when the humid air in the home touches cold glass or a cold frame. It is reduced with less steam and more ventilation, and almost eliminated with low-emissivity double glazing and a frame with a thermal break. If the mist is between the two panes, the seal has failed and the glass unit has to be replaced.

Owners arriving from the UK or Ireland are often surprised to find condensation in a flat on the Costa Blanca at all. In Alicante it is a winter problem and a problem of homes with no central heating: there is humidity inside, the 1980s aluminium glazing sits at the outside temperature, and every morning there are droplets on the glass and a puddle on the sill. Over the years that puddle becomes mould on the seal, on the wall and in the roller shutter box. This guide explains why it happens, what you can do without building work, when it pays to replace only the glass and when the whole window, which costs €350 to €900 per unit, VAT not included.

Solutions to condensation on windows: table from least to most

Start with the cheap options and move up only if needed. This table ranks the solutions by cost and effectiveness.

Solution What it does Effectiveness Cost When to choose it
Cut the steam and ventilate Less humidity in the air Medium-high with double glazing; medium with single Free Always; it is the baseline
Extractor fans in bathroom and kitchen Removes steam where it is produced High as a complement Low If you do not have them or they do not work
Dehumidifier Lowers the humidity of the air Medium; treats the symptom Low to medium plus running cost Enclosed flats, apartments shut up for months
Insulate the roller shutter box Removes the coldest point of the opening High for mould above the window Low to medium Uninsulated built-in boxes
Replace only the glass with low-emissivity double glazing Warmer inner pane High if the frame is acceptable Medium, indicative by size uPVC or thermally broken aluminium frame in good condition
New uPVC or thermally broken aluminium window Insulating frame and glass, airtight closure Very high €350 to €900 per unit, VAT not included Aluminium without thermal break, single glazing, window that does not close properly
Insulated plasterboard lining on the window wall Warmer adjacent wall Complementary €35 to €55 per m² If the wall around the window condenses too

Why windows steam up: humid air and a cold surface

Condensation needs two things: air carrying a lot of vapour and a surface below the temperature at which that vapour turns back into water. Remove either one and it disappears.

Warm air holds more vapour than cold air. When the air of a living room at 20 degrees with high humidity touches glass at 10 degrees, the air next to the glass cools, can no longer hold all its vapour and drops it as droplets. That is why the glass condenses first (it is the coldest), then the aluminium frame (it conducts the cold from outside to inside) and then the wall next to the window and the roller shutter box.

From that come the two routes to a solution: lower the humidity of the air (ventilate, extract, dehumidify) or raise the temperature of the surface (insulating glass and frame, insulating the box, heating). Effective solutions combine both.

A detail specific to Alicante: the problem is worse in flats with no heating, which is most of them, because the wall and the glass sit at the outside temperature while there is vapour inside. Also in coastal apartments with heavy curtains and shutters lowered, which isolate the glass from the room air and make it colder still. And in holiday homes shut up from October to Easter with the shutters down, the air inside never changes and the first visit back is to a musty flat with mould around every window.

Solutions without building work: steam, ventilation and habits

With double glazing in a window in good condition, ventilating and cutting the steam is usually enough for the morning mist to disappear or shrink to a thin band at the bottom of the glass.

  • Cross-ventilation for ten minutes a day, in the morning, with opposite windows open. It clears the vapour that built up overnight.
  • Bathroom extractor on a timer and a kitchen hood ducted to the outside. Bathroom and kitchen produce most of the vapour; if it is extracted there, it does not reach the living room or bedrooms.
  • Do not dry laundry indoors, or do it with the window ajar and the door of that room closed.
  • Lids on pans and the bathroom door closed when showering.
  • Curtains and shutters: at night, do not leave the curtain pressed against the glass or the shutter fully down if you can avoid it; the room air must reach the glass so it does not get so cold.
  • Minimum temperature in bedrooms: a room at 12 degrees condenses far more than at 17.
  • Dehumidifier in enclosed flats, with a tank or a drain. It lowers the humidity of the air and reduces the mist, but it uses electricity and does not fix cold glass; it is a support, not the solution. For a holiday home left empty, a dehumidifier with a drain hose running to a basin is the single most useful thing you can leave switched on.
  • Wipe the glass in the morning with a rubber squeegee and a cloth so the water does not reach the seal or the sill. It does not prevent condensation, but it prevents mould.

If mould has already appeared on the sill, the seal or the wall, treat it before anything else; and if the condensation also affects corners and walls, the problem is more general and we cover it in condensation and mould on walls in Spain and on our damp treatment in Alicante page.

The glass: single, double and low-emissivity

The glass is the coldest surface of the window. Single glazing condenses almost every winter morning; conventional double glazing far less; low-emissivity double glazing with an argon cavity very rarely in Alicante.

  • Single glazing: the glass in the 1970s to 1990s aluminium windows still found in many flats in the centre, Carolinas or Benalúa and in older apartments in Playa de San Juan. It sits at the outside temperature and condenses with any humidity.
  • Double glazing (sealed unit): two panes with a cavity of air or gas between them. The inner face stays considerably warmer. It condenses only with high humidity and low temperatures.
  • Low-emissivity double glazing: one of the inner faces carries an almost invisible metallic coating that reflects heat back into the room. With an argon-filled cavity, it is the current standard. The inner face stays very close to room temperature and condensation almost disappears.
  • Solar-control glass: useful on the Alicante coast for west and south facades, it cuts summer heat; it can be combined with low-emissivity.

If your frame is uPVC or thermally broken aluminium and in good condition, only the glass can be swapped for a low-emissivity double-glazed unit of the thickness the sash will take, without touching the frame. It is an hour's work per window and considerably cheaper than a whole window; it is quoted by size. If the frame is aluminium without a thermal break or iron, changing only the glass helps on the glass but the frame will keep condensing, and the whole window usually pays better.

Mist between the two panes

If you see mist, droplets or whitish stains that you cannot wipe from inside or outside, they are inside the cavity: the perimeter seal of the double-glazed unit has failed (through age, sun or a faulty installation) and humid air has got in. It cannot be repaired: the sealed unit is replaced with a new one made to measure. The frame is kept.

The frame: thermal break and uPVC

An aluminium frame without a thermal break conducts the cold from outside to inside and condenses just like single glazing; a uPVC frame or a thermally broken aluminium frame keeps its inner face temperate.

Aluminium is an excellent conductor, which is bad for insulation. Old aluminium windows are a single continuous piece of metal from outside to inside: the inner frame sits almost at the outside temperature and vapour condenses on it, runs down the bottom profiles and rots the seal and the sill. The thermal break (RPT in Spanish quotes) is a polyamide strip that separates the outer profile from the inner one, so the cold does not pass. Good-quality thermally broken aluminium with low-emissivity double glazing performs very well and withstands coastal salt air and sun better than any other material.

uPVC insulates by itself and needs no break; the inner frame stays temperate and, with low-emissivity double glazing, it is the combination that condenses least. It is also quieter. On the coast, choose quality profiles with internal reinforcement and corrosion-resistant hardware.

We compare materials, prices and timescales in uPVC vs aluminium windows: cost in Spain, and explain the fast installation method in replacing windows without building work. A new uPVC or aluminium window costs €350 to €900 per unit, VAT not included, with removal of the old one, installation and finishing.

The roller shutter box and the wall around it

Replacing the window and leaving the built-in shutter box uninsulated leaves the coldest point of the opening in place: it condenses, grows mould in the strip of wall above the window and lets air through.

In 1960s to 1980s flats in Alicante, Elche, Elda or Benidorm, the roller shutter box is a brick or precast concrete box open to the outside through the shutter slot. Inside, it sits at the outside temperature. Solutions:

  • Insulate the box from inside with insulation panels stuck to the inner walls of the box and to the lid, and seal the joints between the lid and the wall. It is done when repairing or motorising the shutter, taking advantage of the open box.
  • Replace the box with a compact insulated one when the window is replaced: the cleanest solution, usually included in a window replacement with shutter.
  • Line the wall of the window with plasterboard and mineral wool, at €35 to €55 per m², VAT not included, if the whole facade wall condenses and not just the opening.

It is also worth checking the seal between the frame and the wall: old windows have a mortar or silicone joint cracked with age through which cold air and water get in. A good window replacement includes insulating foam and an exterior seal, with tape or a sealant compatible with salt air if you are near the sea.

Condensation on windows in Alicante: old flats and coastal apartments

In our area the problem concentrates in old flats with aluminium without a thermal break and single glazing, and in coastal apartments shut up in winter with high humidity and salt air.

In the centre, the Ensanche, Carolinas, San Blas or Benalúa, 1970s to 1990s aluminium windows with single glazing are the norm in unrenovated flats. Replacing them is, along with insulating the shutter box, the measure with most effect on condensation, street noise and the summer air conditioning bill. In a full home renovation they are always replaced.

In Playa de San Juan, Albufereta, Cabo de las Huertas, El Campello, Santa Pola or Torrevieja, aluminium suffers from the salt air: profiles pit, hardware seizes and seals harden, and the window closes worse every year. Here we recommend marine-grade thermally broken aluminium or uPVC with treated hardware, low-emissivity double glazing and, on west facades, solar control. In apartments shut up for months, a dehumidifier and airing on return complete the solution. If there are also damp patches low on the walls, the cause may be different; see rising damp in Spain: what to do.

Common mistakes

  • Changing the glass and keeping an aluminium frame without a thermal break. The frame keeps condensing and dripping onto the sill.
  • Buying a new window without insulating the shutter box. The mould moves to the strip above the window.
  • Relying entirely on the dehumidifier. It reduces the mist while it runs; it does not fix single glazing or a cold frame.
  • Shutting the home up tight in winter. Without changing the air, humidity rises and condensation worsens.
  • Pressing heavy curtains against the glass and lowering the shutter fully every night: the glass is cut off from the room air and gets colder.
  • Sealing the ventilation grilles to keep the cold out. They are what removes the vapour.
  • Cleaning the mould off the sill every winter and doing nothing else. It is the symptom; the cold glass is the cause.
  • Choosing the window on price alone. Cheap aluminium without a thermal break condenses exactly like the one you had; check it has a thermal break and low-emissivity glass.

When to call a professional

Ventilation, habits and the dehumidifier you apply yourself; insulating a shutter box is advanced DIY; replacing glass or windows and lining the wall are jobs for an installer.

You can do yourself:

  • Cut the steam, ventilate daily and use the extractors.
  • Wipe the glass in the morning and clean the mould off the sill with diluted bleach.
  • Check whether the mist is inside, outside or between the panes.
  • Insulate a shutter box with panels and sealant if you are handy.
  • Check and replace the sash gaskets if they are hard or torn.

Better left to a professional:

  • Replacing a double-glazed unit with a failed seal: it is measured, made and fitted with the correct packers and sealing.
  • Replacing single glazing with low-emissivity double glazing in a frame that will take it.
  • Replacing the whole window, with removal of the old one, insulation of the opening and exterior sealing: a faulty installation lets water and air in and cancels the improvement.
  • Replacing windows on the facade of a building with a community of owners: the external appearance is usually regulated by the community and the work goes through a declaración responsable at the town hall; we handle it.
  • Lining the facade wall with insulation, with the wall made good first.

If you want to stop wiping the windows every morning, we visit within 48 to 72 hours in Alicante and the surrounding area, measure every opening, tell you whether it pays to replace the glass or the window and give you a fixed itemised quote, free and without obligation, with a written guarantee on the work. For a holiday home, we can do the survey with your key holder and send you the quote by email. Book your visit through contact.

Frequently asked questions

Why do my windows steam up on the inside?

Because the air in the home carries water vapour (showers, cooking, laundry, breathing) and, when it touches cold glass or a cold frame, that vapour turns into droplets. The more humid the air and the colder the glass, the more condensation. Aluminium windows without a thermal break and single glazing steam up the most.

How can I stop condensation on windows without replacing them?

By cutting the steam and ventilating: extractor fans in bathroom and kitchen, no laundry drying indoors, cross-ventilation for ten minutes a day, curtains and shutters that do not block the air over the glass, and a dehumidifier if the flat is very enclosed. That reduces it a lot with double glazing; with single glazing or aluminium without a thermal break, it reduces but does not remove it.

Which windows do not get condensation?

None removes it completely if the indoor humidity is very high, but a uPVC or thermally broken aluminium window with low-emissivity double glazing and an argon-filled cavity keeps the glass and frame much warmer and very rarely condenses in Alicante's climate.

What does condensation inside the double glazing mean?

That the seal of the cavity between the two panes has failed and humid air has got in. It shows as mist or droplets that cannot be wiped from either side. It cannot be repaired: the sealed unit is replaced with a new one made to measure, which is fitted without touching the frame.

How much does it cost to replace a window to stop condensation?

Replacing an aluminium or uPVC window costs €350 to €900 per unit, VAT not included, with removal of the old one, installation and finishing. The price depends on size, material, opening type and glass. Replacing only the glass with low-emissivity double glazing, if the frame can take it, is cheaper; we quote after measuring.

Is uPVC or aluminium better against condensation?

uPVC insulates slightly more by nature and the frame stays less cold. Good-quality thermally broken aluminium achieves a very similar result and stands up better to salt air and coastal sun. What makes the difference is that the aluminium has a thermal break and the glass is low-emissivity double glazing; without that, neither avoids condensation.

Can condensation on windows cause mould?

Yes. The water running off the glass soaks the sill, the seal and the surrounding wall, and black mould grows there. If you see mould on the sill or in the corners of the window every winter, condensation is the cause and it has to be treated, not just the mould cleaned off.

Why does the roller shutter box condense more?

Because an uninsulated built-in shutter box is the coldest part of the opening: a concrete or brick box with outside air inside it. Vapour condenses on its walls and on the lid, and mould appears in the strip of wall above the window. The box is insulated from inside and the joints with the wall sealed.

Updated: