# Air conditioning leaking or not cooling: causes

If the air conditioning drips from the indoor unit, in most cases it is a blocked condensate drain, a tray overflowing because the coil has iced up, or a drain pipe running uphill; if it does not cool, the most common causes are dirty filters and coils, an outdoor unit that is blocked, choked or stopped, a wrong mode setting or a refrigerant leak. The drain, filters and settings you can sort yourself; gas, electrics and the compressor are for a certified technician. If the unit is old and not worth repairing, a new split unit installed costs €900 to €1,600, VAT not included.


## Air conditioning leaking or not cooling: the short answer

**If it drips from the indoor unit, switch it off: in most cases it is a blocked condensate drain, a coil iced up from dirty filters or low gas, or a drain pipe running uphill. If it does not cool, the most common causes are dirty filters and coil, a wrong setting, an outdoor unit that is covered or stopped, or a refrigerant leak. The drain, filters and settings you can sort yourself in an afternoon; gas, electrics and the compressor are for a certified technician. If the unit is many years old, a new split unit installed costs €900 to €1,600, VAT not included.**

These are the two most repeated breakdowns in Alicante between June and September, and they share causes: a dirty unit or one low on gas cools worse and, on top of that, ices up the coil and drips. For many British and Irish owners it is also the first thing that goes wrong on arriving at a holiday flat that has sat closed since October. This guide goes by symptom: what to look at, in what order, what each thing means and what you can fix without tools.

## Water dripping from the indoor unit

**Water dripping from the split is condensation that has not gone out where it should. The causes, from most to least frequent: blocked drain, iced coil, drain pipe running uphill or crushed, cracked or loose tray, failed condensate pump and lost pipe insulation.**

| How it drips | Probable cause | Fix | Who |
|---|---|---|---|
| Drips from the centre or one side of the unit, continuously, in cooling mode | Blocked condensate drain, tray overflowing | Clear the drain pipe from the outside end; check water comes out | You |
| Drips in bursts, especially on switching off, after cooling poorly | Iced coil thawing | Clean the filters; if it ices again with clean filters, low gas | You (filters), technician (gas) |
| Drips down the wall under the unit or from the hole where the pipes go through | Drain pipe running uphill, crushed or disconnected along its run | Redo the fall or the section | Technician or installer |
| Drips from the copper pipes or along their run | Insulation torn or missing: the cold pipe condenses | Replace the lagging and tape | You or a handyman |
| Drips with no pattern, unit in an internal room with no fall to outside | Condensate pump blocked or failed | Clean the pump and float; replace if it does not work | Technician |
| Drips even with the drain clear | Tray cracked, displaced, or indoor unit not level | Check and level the unit, replace the tray | Technician |
| Drips outside from the outdoor unit in heating mode | Normal condensation from the outdoor coil | Nothing, except run the water away if it is a nuisance | You |

How to check the drain without tools: with the unit off, find the end of the pipe (on the facade, on the terrace or at a drain) and slowly pour a glass of water into the tray of the indoor unit, in the coil area. If the water comes out at the end within seconds, the drain is clear and the cause is elsewhere. If it does not come out or takes a while, it is blocked: clear it from the outside end with a flexible rod, gentle water pressure or a hand vacuum pump, and repeat the test. In units that have stood idle for months, the usual culprit is a plug of dust, mould or insects in the first few centimetres.

What not to do: carry on using the unit while it drips. The water soaks the plaster, runs down to the skirting and within a week you have a stain and mould; if there is a neighbour below, so do they. The marks it leaves and how to treat them are in [condensation and mould on walls in Spain](/en/guides/condensation-and-mould-on-walls-spain/).

## Not cooling or cooling poorly

**If the unit runs but does not cool, follow this order: remote settings, filters, outdoor unit, ice. That identifies in half an hour whether the problem is yours or the technician's.**

### 1. Settings

It sounds obvious and it is the cause of many call-outs: the unit is in fan mode (fan icon), in dry mode (drop icon) or in auto with a high set point. Put it in cooling (snowflake), the temperature clearly below the room temperature, fan on high, and wait ten minutes. Change the remote's batteries if it responds intermittently. If it has a timer or schedule, switch them off. Spanish remotes often label modes in Spanish: frío is cooling, calor heating, ventilador fan, seco or deshumidificar dry.

### 2. Filters and indoor unit

A loaded filter reduces the airflow: the air comes out cold but there is little of it, the room does not cool down and the coil tends to ice up. Wash the filters, dry them in the shade and try again. If the indoor coil is grey with dust or smells of mould, it needs a deep clean by a technician.

### 3. Outdoor unit

Go and look at it with the unit running. It should be working: the fan turning and blowing out warm air. If it is stopped, the fault is electrical or a protection trip (capacitor, contactor, circuit board, thermal cut-out) and is a technician's job. If it is running, check it is not covered (awning, plants, boxes, cover), that the coil is not coated in dust, fluff or salt, and that it is not in full afternoon sun. A choked or dirty outdoor unit can lose a significant part of its capacity precisely in the hottest hours.

### 4. Ice

Open the cover and look at the indoor coil and, on the outdoor unit, the thin pipe. Frost or ice with clean filters and good airflow almost always means low refrigerant from a leak (or a faulty sensor). Switch the unit off, let it thaw completely (it may drip) and call a certified technician: they will measure pressures and temperatures, find the leak, repair it and vacuum and recharge. Recharging without repairing is pointless.

### 5. Not enough capacity

If the unit has never cooled well, it is not a fault: it is undersized. A small split in a west-facing living room with single glazing in Alicante will not reach 24 degrees in July however clean it is. The options are improving the glazing (see [double glazing and low-E glass in Spain](/en/guides/double-glazing-low-e-glass-spain-what-to-choose/)) or a more powerful unit; we size it in [air conditioning installation cost in Alicante](/en/guides/air-conditioning-installation-cost-alicante/).

| Symptom | Most likely | Can you fix it |
|---|---|---|
| Air comes out at room temperature, outdoor unit does not start | Electrical fault in the outdoor unit | No |
| Air comes out cool but not cold, outdoor unit running | Low gas or dirty outdoor coil | Outdoor cleaning yes; gas no |
| Air comes out cold but weak | Dirty filters, slow fan | Filters yes |
| Cools at first then stops, with ice | Low gas, low airflow | Filters yes; gas no |
| Cools at night but not in the afternoon | Outdoor unit in sun or choked, unit only just big enough | Shade and cleaning yes; capacity no |
| Cools but switches itself off, light flashes | Error code: sensor, overload, communication | Note the code for the technician |
| The RCD trips when it starts | Electrical leak, almost always in the outdoor unit (damp, salt) | No; never bypass the RCD |

## What the technician does and what they should not do

**A serious technician measures before acting: pressures, inlet and outlet temperatures, compressor current and electrical insulation. From that they tell you whether it is gas, electrical, mechanical or sizing, and quote. What they should not do: top up gas without looking for the leak, bypass protection or charge for a visit with no diagnosis.**

What a proper diagnosis includes:

1. **Airflow check and cleaning** of filters, indoor coil and fan.
2. **Pressure measurement** at the outdoor unit with gauges and temperatures with a probe: the difference between inlet and outlet air and the superheat of the gas say whether refrigerant is low.
3. **Leak search** with a detector or with nitrogen and foam at the flare joints, valves and coils. Typical leaks are at the flared connections of the installation (badly tightened or vibrated loose) and, in coastal units, in corroded coils.
4. **Repair of the leak, vacuum and charge** by weight according to the unit's rating plate, with recovery equipment. Only companies certified for fluorinated gases.
5. **Electrical check**: compressor and fan capacitors, contactor, connections, current with a clamp meter, insulation if the RCD trips.
6. **Report and quote**: what it has, what it costs to repair and, if relevant, what it costs to replace.

An honest rule on repair versus replace: if the leak is in a coil, the compressor is damaged or the unit uses a refrigerant that has been withdrawn from the market, the repair can cost more than half of a new unit, with no guarantee. In that case replacement makes sense: a split unit installed, with a correct electrical line and drain, costs €900 to €1,600, VAT not included. If the fault is a capacitor, a flare joint or a drain, it is repaired and that is that.

## Typical cases in Alicante

**In Alicante, the local causes we see most are salt air on coastal outdoor units, drains "to the open air" dripping onto the street in older buildings, and holiday apartment units starting up after months idle.**

- **Playa de San Juan, Albufereta, El Campello, Santa Pola, Guardamar, Torrevieja, Benidorm.** Corroded outdoor coils losing gas and performance, corroded connections tripping the RCD, rusted brackets that vibrate. A coastal outdoor unit that is never rinsed with fresh water lasts a good deal less. See [air conditioning in Torrevieja](/en/air-conditioning-torrevieja/) and our [renovations in Benidorm](/en/renovations-benidorm/) page.
- **Centro, Carolinas, San Blas, Benalúa, El Pla.** Old installations with the condensate drain taken out to the facade: it drips onto the pavement or the neighbour's awning, and is a cause of complaints; in general, by-laws and communities of owners require it to be run to a drain. Also units hung off the socket circuit and old consumer units. When repairing, it is worth regularising the drain and the line.
- **Holiday apartments.** Switched on in July after nine months idle: a plug in the drain, mould in the tray, insects, flat batteries. It is the first-weekend drip. Clean on arrival and test before it gets hot; if you are not there, put it on your key holder's or management company's pre-season list.
- **Villas with ducted systems.** The drip appears in the false ceiling and is mistaken for a roof leak; the cause is the indoor unit's tray or the drain. Before opening the ceiling looking for a water leak, try switching the air conditioning off for two days.

We work across the province with climate technicians and, for small repairs (drain, insulation, bracket, pipe), with our partner [Manitas Costa](https://manitascosta.es/en/).

## Common mistakes

- **Carrying on using the unit while it drips.** Stain, mould and the neighbour below.
- **Topping up gas every summer without looking for the leak.** Money wasted and emissions; the leak is still there.
- **Buying a recharge kit online.** No certification, no vacuum and a risk of mixing gases: you can end up with a dead compressor.
- **Running the unit with ice on the coil.** The compressor can draw in liquid and fail.
- **Covering the outdoor unit so it cannot be seen or to protect it from the sun.** It chokes; shade is fine, a cover or a closed cabinet is not.
- **Bypassing the RCD that trips with the air conditioning.** There is an electrical leak; without the RCD, a person takes the risk. If the board itself is old, see [old consumer unit in Spain: when to replace it](/en/guides/old-consumer-unit-fuse-box-spain-when-to-replace/).
- **Leaving the drain dripping onto the street or the neighbour's terrace.** Complaint, by-law and, in a block, conflict. It is run to a drain.
- **Blaming the unit for an insulation problem.** A west-facing living room with single glazing needs better glazing, not a bigger split every three years.

## When to call a professional

**Remote settings, filters, clearing the drain, pipe insulation and cleaning the outdoor unit are within your reach with the unit switched off at the mains. Gas, electrics, compressor, condensate pump, trays, levelling and any work on the facade or at height: a qualified technician, and for refrigerant, a company certified for fluorinated gases.**

Do it yourself:

- The six diagnostic steps in this guide.
- Clear the drain from the outside end if it is accessible without risk.
- Replace the pipe insulation within your reach.
- Note the model, the error code if the light flashes and what you have tried: it saves the technician time, and it is the information to send if you are arranging the repair from abroad.

Call a technician:

- Ice with clean filters, air cool but not cold, or the outdoor unit stopped.
- Dripping that continues with the drain clear.
- Noises, a smell of burning or an RCD that trips.
- Outdoor unit on the facade or at height: do not lean out.
- Condensate pump that does not start.
- An old unit with an expensive fault: so they tell you plainly whether replacing it makes sense.

If your air conditioning drips or does not cool and you want someone to diagnose it without selling you gas, we visit within 48 to 72 hours in Alicante and the surrounding area, measure, locate the cause and give you a free fixed quote for the repair or for a new unit installed, with qualified technicians, a written guarantee and updates in English by photo or video if you are not in Spain. Book your visit through [contact](/en/contact/).